Question:

2018 Coachmen Mirada LS35 After all jacks up rear light blinks and right light is steady? Although all jacks appear to be up?

0

Expert Reply:

Sounds like you might have an out of stroke error on your Lippert Ground Control system that you need to clear. This is pretty easy actually. To clear the error you need to extend all of the jacks in the system at least 6 inches. Then press and hold the retract button until the jacks start to retract. All of the jacks should fully retract and the error should be cleared.

Or sometimes the zero point needs to be reset which we can help with that as well.

1. In manual mode, run the jacks to level the trailer. This is best achieved by placing a level in the center of the trailer and leveling it both front to back and then side to side. (See “Basic Jack Operation” for instructions on how to manually operate the system).
2. Once the trailer is level, turn off the touch pad.
3. With the touch pad off, press and release the “FRONT” button five (5) times and then press and release the “REAR” button five (5) times.
4. The touch pad will flash and beep and the display will read “ZERO POINT CALIBRATION ENTER to set, Power to Exit”.
5. To set the current position as the zero point, press the “ENTER” button.
6. LCD display will read “Zero point stability check”.
7. LCD display will read “Zero point set successfully” once process is complete.
8. The system will set this point as its level state and the touch pad will turn off.