Troubleshooting LF Error Code on Lippert Ground Control 3.0 6-Point Set But Manually Works  

Question:

On a lippert 6 point leveling system, I tried resetting the system, still shows error with LF jack. Manuel operation is still working. How do I reset to get the error fixed?

0

Expert Reply:

To reset the LF error code on your Lippert Ground Control 3.0 6-Point Set # LC675817 you need to extend all of the jacks at least 6" and the press and hold the retract button until all of the jacks are retracting.

While this does clear the code, if you don't investigate the reasoning behind the code it will just happen again. You want to look for any loss of power that might be happening to the jack. Make sure the jack is getting power and all of the wiring to it is intact and in good working order.