Atwood RV Water Heater G6A8E Will Not Switch Over to Gas
Question:
AT96121 will not light and running on full electric for months, full propane tank. The title says it all. I cannot find any kind of cut off switches from manuals. I have turned off reset the fuse box and the internal in trailer control box. Can you think of anything!
asked by: Douglas C
Expert Reply:
I spoke to my contact at Dometic (Atwood) about the issue you are having with your Atwood RV Water Heater part # AT96121. If there is no spark coming from the electrode then there is a problem with the control board and it will need to be replaced. For this we have the Replacement Control Panel for Atwood Water Heaters part # AT91367.
If there is a spark coming from the electrode then there is an issue with the gas control valve, the Replacement Gas Regulator for Atwood Gas RV Water Heaters part # 91602.
Products Referenced in This Question
Replacement Control Panel for Atwood Water Heaters
- Accessories and Parts
- RV Water Heater
- Control Panel
- Atwood