Question:

I have what I believe to be a Ventline Ventadome Trailer Roof Vent V2092SP-25. This lid has the plastic ramp for the actuator molded in the lid. The plastic lid is in bad shape rotten I would like to replace with a metal lid BV0534-00. Would I be able to buy a metal lid and the correct actuator BV0115-04 or do I need to buy a whole new vent assembly V2110SP-24 ? Also on the same trailer I have a Replacement Exterior Pop-Up Roof Vent - Steel - 13-1/2inch x 8inch - Black, and the cover and attaching mechanism is missing, can these parts be obtained or do I have to buy a new vent? Thanks!

0

Expert Reply:

If the vent you have installed on your trailer has a 4-point hinge like the attached photo, part # BVD0449-A01 would be the replacement lid for your Ventline roof vent. We do not offer a metal replacement lid with a 4-point hinge.

The replacement knob and operator you asked about for your fan is part # BVD0462-00.

If you want to replace the vent with one that has a metal lid I recommend part # V2110SP-24. This will fit in a rough opening that measures 14-1/4 inches wide x 14-1/4 inches long.

For the smaller popup vent you mentioned I recommend part # RV-626-062-2756. This is a 1313-3/8 x 7-3/4 inch popup vent. This is a rust-proof aluminum vent and it has a black plastic garnish for the interior. The rough opening needed for this vent is 11-1/8 x 5-1/2 inches.

I recommend using a good silicone sealant like part # 0160297 when installing these vents. If you need mounting screws as well I recommend part # 30587 if you are mounting it wood and part # 31071 if you are installing the vents in metal.