Question:

Can you surface mount it on the rear of the unit or does air flow need the rear to be open? Basically moving air between compartments. If so which way is the warm air blown?

0

Expert Reply:

I went ahead and checked the mounting instructions for the Progressive Dynamics RV Power Control Center with AC/DC Panel and Converter/Smart Charger - 35 Amp # PD4135K and it states that the:

The PD4100 series POWER CONTROL CENTER should be installed horizontally (converter section to the right).

-Unit is NOT ignition protected.

-Do not mount in the LP gas or the battery compartment.

-The INTELI-POWER converters are not designed for zero clearance compartments.

-The POWER CONTROL CENTER is not designed for wet or damp locations. Install in an interior / dry location.

-Cut mounting hole to approximately 6-7/8” x 10-1/8”.

-The OEM should test the POWER CONTROL CENTER converter under full load conditions in its intended mounting location to ensure proper ventilation. Failure to provide adequate ventilation will prevent the converter from supplying full output power.

Attached is a review video for you to check out as well.

expert reply by:
0
Bryce D

Product Page this Question was Asked From


Q & A Icon

Continue Researching

See More Q&A Expert Answers >>