bing tracking image
Q & A Icon

What Wire Gauge Should Be Used When Installing the C-800 Klauber Stabilizer Motor  

Question:

I am adding a third stabilizer and need to know what gauge wire to use to send power to the motor. I have a new switch that uses 16 gauge. I would think number 12 would work with this but not sure? What gauge wire is recommended for this 20 amp max circuit? Thanks

0

Expert Reply:

When installing the C-800 Klauber Stabilizer Jack Motor, # LC138445, the largest gauge wire possible should be used.

I recommend 10 gauge wire running from the battery to the 20amp breaker and then to the motor. As well as on the motors ground circuit. I recommend using # 10-2-1 wire. The wire is sold by the foot and is a jacketed 2-10gauge wire. I also recommend the Deka Heat Shrink 12-10 Gauge Butt Connectors, # DW05745-5 and 2- Deka Ring Connectors, # DW05740-1 to connect to the circuit breaker.

expert reply by:
0
Jared P

Products Referenced in This Question




Product Page this Question was Asked From


Q & A Icon

Continue Researching

See More Q&A Expert Answers >>