Question:

Hi I have a wireless one ezy mount system installed on my 2018 f250 and I’m having issue with it ping air while I’m driving. I’m using the app and have 3 preset numbers set being 5, 45 and 60 psi and on the remote have 5 and 45 psi. While driving at the default 5 psi I have no issues but as soon as I hook up and haul at either 45 or 60 psi while driving I here the air deflate and and it always s to 23 psi, once I check the app it’s still showing the preset number I have but as soon as I press the increase button it shows current pressure as 23 psi and than reinflates to the preset psi. I have tried using both the remote and app and the same is happening. I don’t have 23 psi locked into either remote or app any idea why this would be happening

0

Expert Reply:

I reached out to Air Lift about your Air Lift WirelessONE Compressor System for Air Helper Springs # AL25980EZ. They said that more than likely this is a ground issue. Make sure your ground connection is secure on a clean, bare-metal surface. If that does not solve the problem then it is likely a bad manifold.