bing tracking image
Q & A Icon

Troubleshooting the Comp Freeze Error Code on Air Lift Compressor Remote  

Question:

My remote comes up with comp freeze and want go up or down

0

Expert Reply:

According to Air Lift, there are a few things that can cause this issue. The problem is likely an air leak between the manifold and the compressor or simply a weak compressor that would need to be replaced.

To get the compressor running again so you can check for leaks, you can simply either undo your power and ground connection for 30 minutes or try pulling the fuse and resetting them. You can also clear the code from the app on your phone in Settings - Troubleshooting - View and Clear codes.

This should get the compressor running again so you can use some soapy water to check for leaks. If you find leaks, then simply tighten the fittings and that should solve your problem. If there are no leaks and you have the problem again, then you will need a new compressor. This kit has a 2 year warranty, but if you are outside of your warranty, then you will want to buy a new compressor which is # AL75FJ.

expert reply by:
0
John H

Product Page this Question was Asked From


Q & A Icon

Continue Researching

See More Q&A Expert Answers >>