Question:

my Lippert Ground control leveling system lcd touch pad screen lights up but shows no read out is there any way to reset the touch pad so i know what i doing

0

Expert Reply:

I'm assuming you have a Lippert Ground Control 3.0.

In some cases, we've found that simply disconnecting the control panel for about 15 minutes or so will reset the panel and it'll work fine. If that doesn't do the trick, check the 15A fuse on the feed to the control panel and the 35A fuse on the feed to the control module. Check that 12V power is reaching the control module and the control panel, then verify that the ground connections are secure and not corroded.

If all that checks out, the control panel is faulty and would need replacing. The # LC421484 will be the correct panel for Ground Control # LC358590, or # LC675817 and is also compatible with the Ground Control TT, # LC672136.

expert reply by: