Expert Answers about Generators


  • Troubleshooting etrailer 3,200-Watt Portable RV Inverter Generator Bogging Down Under Load
  • In regards to the 3,200-Watt Portable RV Inverter Generator, if you look in the owner's manual at the end you'll see a troubleshooting section. In this section, it states that if the unit bogs down under load but not while running without a load, you could be suffering from the following causes: 1. Short circuit in a connected load. 2. Engine speed is too slow. 3. Generator is overloaded. 4. Shorted generator circuit. 5. Clogged or dirty fuel filter The corrections for these causes are...
    view full answer...

  • Troubleshooting etrailer 3,200 watt Inverter Generator Dying After High Altitude Jet Installation
  • The High Altitude Jet for 3,200-Watt etrailer Generator # 333-330717002 is designed to be used on the 3,200-Watt Portable RV Inverter Generator 333-0003 (W02983) at an altitude of 3,000' to 6,000'. If you are lower than that it can cause the generator to run inconsistently. If you are at the correct altitude then there are a few things to look into that have more or less to do with maintenance. I'm attached a clip from the instructions for troubleshooting the generator. If you've checked...
    view full answer...

  • Troubleshooting An Open Ground Error When Using A Surge Protector With Generators
  • Your generators have a floating neutral so that's why you're receiving the open ground error. The solution to this is to plug the Hughes Autoformers Ground Neutral Bonded Plug for Generators # HU33FR into an open 15 amp outlet on the generators. You CAN NOT plug this into any outlets in your Lance 650, only on the generators. These plugs will clear your open ground error and allow your surge protector and generators to properly function.
    view full answer...

  • Camco Gen-Turi RV Generator Exhaust System Operation In Heavy Rain
  • The Camco Gen-Turi RV Generator Exhaust System # CAM44461 is a very basic exhaust extension, so your question about rain is valid. I reached out to the manufacturer and they said that there isn't an issue with any large amounts of water getting into your generator exhaust. The engineer stated that they have holes where the bolts go through and water will drain out there. They said if it were an issue, they would have added an additional part like a chimney cap, but it has not been needed....
    view full answer...

  • Troubleshooting A-iPower 2,000 Watt Generator Shutting Down After 20 Minutes Powering Refrigerator
  • I reached out to my contact at A-iPower to get his thoughts on why your 2,000 Watt Inverter Generator # 289-SUA2000i might be shutting down after 20 or so minutes when trying to power your refrigerator. He did say that the 2,000 watts starting and 1,600 watts running power output on this generator should be enough to power up just about any refrigerator on the market, but he's thinking there's something in the background that's also consuming power from the generator. Typically this would...
    view full answer...

  • Troubleshooting a A-iPower 2,000-Watt Portable Inverter Generator Not Starting
  • Some common issues when trying to start a generator like the A-iPower 2,000-Watt Portable Inverter Generator # 289-SUA2000i are: 1. It’s low on oil. This generator requires 10W-30, you'll want to fill the oil until the upper mark of the dipstick is met. 2. It’s out of gas. Ensure the gas tank is full and that the gas is not stale. 3. The choke lever is in the wrong position. The starting dial switch needs to be in the starting position. 4. The fuel valve is closed or clogged. Check...
    view full answer...

  • Troubleshooting A Furrion Chill Replacement RV Air Conditioner That Wont Run On Generator Power
  • Since everything is working when hooked up to shore power the generator power is most likely the issue. The Furrion Chill Replacement RV Air Conditioner for Coleman Setup # FR42PV is going to require 3,000 watts starting power and 1,620 watts running power. If your generator doesn't have the capacity for that then I recommend the 4,500-Watt Portable RV Generator # 333-0005. This generator is rated for 4,500 starting watts and 3,600 running watts and can run off of propane or gas. It has...
    view full answer...

  • Generator Will Shut Off After Running for a Minute
  • There are a wide variety of things that could be causing your generator, like the A-iPower # 289-SUA2000I, to shut off after a minute of running it. The common things to check for are making sure it has enough gas, that the gas is not old, how long it has been since the generator was started, if the battery is strong, and if you have a plugged fuel line. If it has been a while since the generator was started or if the gas is old it could have plugged a fuel line or gummed up the carburetor....
    view full answer...

  • Troubleshooting A-iPower Generators That Will Run On Propane But Not Gas
  • If your A-iPower 3,800-Watt Portable Inverter Generators # 289-SUA2000i-2 are not running on gas but will with propane than your carburetor is most likely clogged and would need to be removed and cleaned in order to get your generators up and running again.
    view full answer...

  • Troubleshooting A Furrion RV Air Conditioner That Isnt Running Off Of Generator Power
  • If the Furrion Chill Replacement RV Air Conditioner for Coleman Setup # FR42PV is running on shore power but not when running off of generator power the issue lies with the generator. Do you have anything else running when you're trying to start the air conditioner? If so, you could be falling the below the the necessary wattage required to start the unit. For example typically an RV microwave is going to require 1000 watts while running, an RV fridge is going to need 600 watts to start...
    view full answer...

  • Troubleshooting A Power Supply That Will Not Switch From Shore Power To Generator Power
  • If your generator is running at 147v that sounds like your generator is running too high and the voltage needs to be adjusted. Additionally, if you have no already, check the generator breakers and see if they've been tripped. If they have tripped, reset the breaker back to the ON position and check again for functionality. If your breakers are fine, then most likely the ATS is your issue, and at that point you'll need to have a qualified service professional come and check your ATS out. The...
    view full answer...

  • Troubleshooting the AC Output Not Working on the A-iPower 2,000-Watt Portable Inverter Generator
  • If the A-iPower 2,000-Watt Portable Inverter Generator # 289-SUA2000i is running but AC power is not available, you have one of the below issues going on. 1. AC Circuit breaker is open. 2. Fault in generator. 3. Poor connection or defective cord set. 4. Connected device is bad. To reset the AC circuit breaker, you will need to have the circuit breaker in the off position and restart the generator. Then put the breaker back in the on position. If you the AC output is still not working,...
    view full answer...

  • Troubleshooting A-iPower 2,000-Watt Portable Inverter Generator Not Starting
  • Along with the following steps for troubleshooting the A-iPower 2,000-Watt Portable Inverter Generator # 289-SUA2000i, I'm also attaching a cutout from the troubleshooting instructions for this generator. If none of this works then you'll need to take it to a shop that can service generators so they can physically inspect everything. I believe these are the things you said you've checked already: 1. It’s low on oil. This generator requires 10W-30, you'll want to fill the oil until the...
    view full answer...

  • Camco RV Power Defender Voltage Protector - 50 Amp Showing Open Neutral When Plugged Into Generator
  • If you are connecting the Camco RV Power Defender Voltage Protector - 50 Amp, # CAM55306, directly to the generator and getting an "Open Neutral" fault when then connecting to RV you most likely have an issue either with the generator outlet the cord running to your RV. I recommend inspecting the outlet, and the RV's power cord for damage, wear or loose connections.
    view full answer...

  • Is A Start Capacitor Available for the Atwood Air Conditioner
  • Atwood does not make, nor recommend, a start capacitor for their air conditioners. The Atwood # AT15027-22 15,500 BTU air conditioner that you referenced is rated to "run" at 11 amps, whitch at 120V AC = 1320 watts. In the absense of a start capacitor, the general rule of thumb is that you need double the amps to start an air conditioner. In this case, double 1320 watts is 2640 watts. The 3795 watts you mentioned does seem high. By the way, if you are talking about the EU2200i generator,...
    view full answer...

  • What Does Open Ground Error Code Mean for 30 Amp Shore Power Socket
  • A single yellow light on the Camco RV Power Defender, part # CAM55312 that you referenced indicates an open ground like you can see on the picture I attached. This is typically caused by a broken wire or bad connection in side the socket/plug of your generator. So what this means though is that your 30 amp power socket can STILL work since your electrical path is between the hot and neutral pins. The ground is a path in case of a short in equipment. So basically you don't have as safe...
    view full answer...

  • Troubleshooting Remote Issues On A Firman Portable Generator
  • The remote on the Firman 10,000-Watt Portable Generator - 8,000 Running Watts - Gas - Remote Start Item # 333-P08003 will only work if the engine switch is in the run position and the battery switch is in the run position. If you have both switches in the correct position then the next thing to check is the battery in the remote. If the battery is good then you'll need want to reprogram the remote. I've attached the steps to do so. If the remote still isn't working you may have a defective...
    view full answer...

  • Troubleshooting An A-iPower Generator That Starts But Dies When Switched To Run Position
  • Typically if your A-iPower 2,000-Watt Portable Inverter Generator # 289-SUA2000i will start but dies after switching over to run you're dealing with a fuel issue. This could be a lack of fuel, bad fuel, or debris clogging up the fuel line. Your carburetor could also be clogged, which is very common if the generator sat for awhile with fuel in it. I recommend siphoning out the fuel you have in it and cleaning out the carburetor and then refilling with fresh fuel.
    view full answer...

  • Troubleshooting Multi-Switch on A-ipower Parallel Generator
  • The housing on the switch may not be as sturdy as the other parallel generator, but as long as it functions properly I wouldn't be concerned. You can always look at the housing to see if it has any issue or if the fit is simply not as tight but all the connections are still firm and correct. If you bought them recently there is a 1 year parts and labor warranty as well as a 2 year parts replacement warranty. It could very well be that the switch just needs tightening, but it could be...
    view full answer...

  • Troubleshooting an etrailer 4,500-Watt Generator That Will Start But Stops Running
  • If your 4,500-Watt Portable RV Generator # 333-0005 is starting and then not running, there are a few things that you can try/ensure are done properly. I have included a picture that includes troubleshooting issues and how to correct them. I would start by checking the oil level, air filter and ensure that the gas is not stale or got water in it.
    view full answer...