Question:

Hello, Hope all is well. I couldnt start my generator. I have so far charged the battery and filled gas. I choked it too. Used both hand crank and electric start. I also replaced the sparkplug. Starter turn but the engine doesnt fire up. What else can I do? Thanks! Regards

0

Expert Reply:

The only other thing I'd recommend doing is to disconnect the regulator from propane tank and reconnect it turning the propane valve on slowly.

If you've already tried this, then the regulator is probably the issue and would need to be replaced with the Replacement Automatic Voltage Regulator for etrailer 4,500-Watt Portable Generator w/ Electric Start # 333-336713518.