Troubleshooting Lack Of Power To DC Appliances With The Progressive Dynamics PD4045KA Power Center  

Question:

I have installed the PD4045KA. I have A/C power and 13.6 V at the converter positive and ground lugs. I checked the reverse battery fuses and they are good. The reverse battery indicator light is not on or flashing. I have 13.6 V to the right side of individual DC fuse ports. No reading at the left side and when a fuse is ed, Im not getting any power to my appliances with the black DC wire connected and the white wire grounded to the frame. I tested the appliance by connecting it directly to the battery terminals and it works. Any thoughts? Is there any indicator flashing light that the DC converter is functioning properly?

0

Expert Reply:

If you're getting power through the Progressive Dynamics 4000 Series Mini RV Converter w/ Charge Wizard and AC/DC Distribution Panel # PD4045KA to only one side of the fuse then the fuse is the issue. The fuse is just a break in power so if only one side has power nothing is going through the fuse out to the appliance. I recommend swapping out the fuse with a new one and seeing if the issue persists.

If you get power on both sides of the fuse and still no power at the appliance then there's a break somewhere in the wiring between the fuse and appliance.

expert reply by: