bing tracking image
Q & A Icon

How To Test The Converter Output Voltage Of The Progressive Dynamics PD4060 Power Center  

Question:

Just installed the PD4560A in my toy hauler. I have power coming in the the distribution center. I have power going to the converter but no power coming out. Could this just be a bad one and need to replace. Bought from etrailer.

0

Expert Reply:

To test the converter section voltage output of your Progressive Dynamics RV Power Control Center # PD4560K18LS8 you'll need to be connected to AC shore power and then remove the reverse polarity fuses. You can then place the positive probe of your multimeter in the "Converter POS" post and negative probe of your multimeter in the "Converter GND" post.

Most likely the converter is fine and you just have a blown fuse but you can follow the steps above to test the converter output and we can go from there to determine the solution to your issue.

expert reply by:
0
Kevin C
Testing Converter Output Of PD4060
Testing Converter Output Of PD4060
(click to enlarge)
PD4060 Installed
PD4060 Installed
(click to enlarge)
PD4060 Not Showing Voltage