bing tracking image
Q & A Icon

Which Lower Vent Assembly Fits Advent 13.5k BTU RV AC Units  

Question:

Is this compatible with the Advent 13,500 BTU roof top RV AC unit?

0

Expert Reply:

We have lower vents that fit the Advent AC unit you have like with the part # ACRG15 but the Atwood vent you mentioned would not work as it was designed only for Atwood units.

expert reply by:
0
Jameson C

Jackie S.

7/27/2020

What does an E4 message mean.

Etrailer Expert

Jon G.

8/4/2020

The "E4" code for the Air Distribution Box w/ Wall-Mounted Thermostat # ACRG15 means that there is an outdoor ambient temp sensor defect. The solution is to check the wire connections and ensure that the sensor is properly installed, and if it is but it's still malfunctioning then you need to replace the sensor.

Jackie S.

8/5/2020

@JonG It does Not have a wall mounted thermostat. Thanks for the information.

Products Referenced in This Question



Video/Article/FAQ this Question was Asked From

Article or Video
Q & A Icon

Continue Researching

See More Q&A Expert Answers >>