How to Connect the Replacement Lippert Power Gear Manual Leveling Control Kit Wiring  

Question:

So I understand the two supplied harnesses plug into the back of the new controller. I also understand that the red wire is spliced into the orange wire at the pump. My question is are the other two connectors on the provided harnesses plugged into the existing harnesses that remain after removal of the old obsolete controller that is being replaced or do those two new harness plugs get run all the way back and plug in near the pump assembly??

0

Expert Reply:

The plug that includes the red wire from the Replacement Lippert Power Gear Manual Leveling Control Kit # LC359259 will plug into the back of the control panel and then the other end will plug into the connector coming off of the pump.

The other harness that has the smaller connectors will plug into the back of the control panel and then into a matching connector that is spliced into other functions.

Basically these are plug and play aside from that orange wire. You should be able to trace your current wiring to see where it plugs in since these are a direct replacement.

Attached is a wiring diagram to assist you as well.

expert reply by:
0
Jon G
Power Gear Control Panel # 500210 Wiring Diagram
Power Gear Control Panel # 500210 Wiring Diagram